35KV High Frequency Resistor Installed Ground For Wind Power Generation Testing

35KV High Frequency Resistor Installed Ground For Wind Power Generation Testing

    • 35KV High Frequency Resistor Installed Ground For Wind Power Generation Testing
    • 35KV High Frequency Resistor Installed Ground For Wind Power Generation Testing
    • 35KV High Frequency Resistor Installed Ground For Wind Power Generation Testing
  • 35KV High Frequency Resistor Installed Ground For Wind Power Generation Testing

    Product Details:

    Place of Origin: Dongguan,China
    Brand Name: Fullde
    Certification: CE, ISO9001
    Model Number: FNGR-35KV-340A-60Ω-10S-23

    Payment & Shipping Terms:

    Minimum Order Quantity: one set
    Price: Negotiable
    Packaging Details: Wooden packaging,Carton packaging
    Delivery Time: 15 working days
    Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability: 100 Sets per Month
    Detailed Product Description
    Dimensions: 1600*2600*2550 Cabinet: IP23
    Power Frequency Withstand Voltage: 95KV/min Fault Current: 340A
    Rated Resistance: 60Ω±5% Rated Voltage: 35KV

    35KV 340A Neutral Grounding Resistor for Wind power Electric Field

     

    Brief introduction: Resistance grounding has become more widely used for the urban power grid with cables.However,for the grid with"△"connection for transformer winding,when the neutral point needs to be grounded,"Z"type transformer shall be added and then,grounding resistor is installed to the neutral point of "Z"type transformer to prevent the damage to the HV canles and other electrical equipment by sudden short circuit and intermittent arc overvoltage and increase the reliability of the power system operation.

     

    Main features:


    If our neutral grounding resistor is installed, the ground fault current will be reduced significantly when
    compared to ungrounded system. At the same time, the voltage increase of un-faulted phase is also lowered
    obviously, and the zero sequence voltage is only half the value of ungrounded system when single phase
    ground fault occurs.
    In this regard, our neutral grounding resistor could reduce transient overvoltage and eliminate resonance
    overvoltage when a ground fault of one phase takes place, and a simple protective relay can locate and clear the fault. So, this power resistor is highly recommended to protect electrical system and corresponding
    equipment.

     