Home ProductsNeutral Grounding Resistor

11KV 200A Transformer Neutral Grounding Resistor With Quick Thermal Dissipation

11KV 200A Transformer Neutral Grounding Resistor With Quick Thermal Dissipation

    • 11KV 200A Transformer Neutral Grounding Resistor With Quick Thermal Dissipation
    • 11KV 200A Transformer Neutral Grounding Resistor With Quick Thermal Dissipation
  • 11KV 200A Transformer Neutral Grounding Resistor With Quick Thermal Dissipation

    Product Details:

    Place of Origin: Dongguan,China
    Brand Name: Fullde
    Certification: CE, ISO9001
    Model Number: FNGR-11KV-200A-31.8Ω-10S-30

    Payment & Shipping Terms:

    Minimum Order Quantity: one set
    Price: Negotiable
    Packaging Details: Wooden packaging,Carton packaging
    Delivery Time: 15 working days
    Payment Terms: L/C, D/A, T/T, Western Union, MoneyGram
    Supply Ability: 100 Sets per Month
    Detailed Product Description
    Rated Voltage: 11KV Rated Resistance: 31.8Ω±5%
    Fault Current: 200A Rated Frequency: 50Hz/60Hz
    Weight: 300KG Protection Degree: IP30(indoor)

    11KV 200A Generator Neutral Grounding Resistance with 30KVA Transformer

     

    Product key features:

     

    1. Quick thermal dissipation: Plate shaped structure with large area,dissipation is quick;

     

    2. The product series use the imported stainless steel as the resistor component,the temperature coefficient is small and the stability is high;

     

    3. Effective protection,stable features,thus the safety and effectiveness of protection is improved;

     

    4. Flexible assembly and easy to use;

     

    5. Strong technical strength and satisfactory service.

     

    Introduction:


    NGR was used for the 6 ~ 35kV cable power supply system grounding capacitance of the larger current system to reduce the power grid over-voltage, improve the safety of the power grid, reliability. Neutral Grounding Resistors cubicle is a complete set of equipment specially used for the power generator’s neutral point adapts the high resistance grounding. Generator Neutral shall be Non-effectively earthed through a single phase transformer with its secondary winding loaded with a suitable resistance. This method permits sensitive ground fault protection and at the same time limits the ground fault current to a low value, thus minimizing damage at fault point.

     

    More pictures about NGR:

     

    11KV 200A Transformer Neutral Grounding Resistor With Quick Thermal Dissipation11KV 200A Transformer Neutral Grounding Resistor With Quick Thermal Dissipation

     

    Contact Details
    Guangdong Fullde Electrical Technology Co., Ltd

    Contact Person: Chenlinlin

    Send your inquiry directly to us (0 / 3000)