Home ProductsGenerator Load Bank

1KW - 10MW Electric Generator Load Bank Testing Test Output Power Of Generator

1KW - 10MW Electric Generator Load Bank Testing Test Output Power Of Generator

    • 1KW - 10MW Electric Generator Load Bank Testing Test Output Power Of Generator
    • 1KW - 10MW Electric Generator Load Bank Testing Test Output Power Of Generator
  • 1KW - 10MW Electric Generator Load Bank Testing Test Output Power Of Generator

    Product Details:

    Place of Origin: Dongguan,China
    Brand Name: Fullde
    Certification: CE, ISO9001
    Model Number: LB-1000KW-400V

    Payment & Shipping Terms:

    Minimum Order Quantity: one set
    Price: Negotiable
    Packaging Details: Packaged by Wooden Case with Soft Protective Material
    Delivery Time: 25 working days
    Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability: 100 Set/Sets per Month
    Detailed Product Description
    Cooling Mode: Forced Air Cooling, Horizontal Inlet Air And Upwards Exhaust Cooling Accessories: Switch: ABB, Siemens And Schneider, PLC: Panasonic And Siemens;
    Way Of Working: Continuous Working Load Tolerance: ±5%
    Dimensions: 3000*2000*2000 Weight: 2000kg
    Power: Electric

    Container Type 1000KW-400V Generator Load Bank for 800KW Generator

     

    Typical Applications:

     

    1. In the acceptance inspection of load bank, the relevant department have to check whether the new devices fulfill the actual requirement.


    2. After the installation of noise reduction devices, the loading capability must be test again.


    3. For the routine test & maintenance, it is essential to test the output power and loading capability.

     

    Main features of the generator load bank:


    1. Power: 1KW-10MW


    2. PF: 0.8-1.0


    3. Fans cooling or water cooled


    4. Inductive / Resistive or non-inductive


    5. Manual/PLC remote control


    6. Load steps(by switches) / infinite adjust


    7. Current: 0.1A-10000A


    8. Working voltage: DC/AC 1V-1000V


    9. Value: 0.01Ω-100KΩ


    10. Working Environment:
    Altitute: ≤2500m
    Temperature: -10°C~50°C
    Humidity: ≤95%RH
    Working Mode: Continuous work


    11. IP class: IP20-IP67


    12. Nice appearance, reasonable structure;
    Good sealing: be able to work under rain, snow, dust, or any other harsh environment.

     

     

    Introduction of the generator load bank:

     

    Power generator intelligent testing system can accurately test the output power and loading capacity of various generator units,test all the electric parameters including dynamic parameters of generator units,and mainly consists of two parts:testing control and load cabinet,which is used in coordination with host computer thus materializing intelligentization and automatization to complete the testing of all electric parameters of generator unit,meanwhile,charts,curves and testing report are produced,and no manual operation is required(intelligently controlled,manual/automatic may be selected),to provide scientific testing means for large power generator units.

     

     

    Technical Parameters for reference:

     
    System components Load bank, resistive load,data collection, automatic control and manual control, electrical control, cooling devices and auxiliary control,Industrial machines, printer.
    Total discharge power 1000KW
    Resistive load stalls step: 5KW
    Test voltage Three-phase AC400V
    Test Frequency 50Hz
    Resistance tube Insulation resistance of each resistor above DC500V 100MΩ , Pressure AC2000V 1 minute, Resistance to high temperature.
    Load connection Star (three-phase four -wire)
    Loading precision ±3%
    Work way Continuous work
    Working power 480VAC/50Hz/Three-phase four-wire system; (reservation terminals)
    Operator terminal IPC / software, full realization of automated control
    Control mode Manual control / computer software auto control
    Measured Control Function Load subtraction control, extended load automatic identification synchronization control
    IPC detection function I, V, HZ, KW, COSΦ etc.Real-time display, electrical performance testing, curves and report output, system electrical parameters monitoring, automatic data acquisition;
    Parameter record Form through EXCEL, curves pictures saved by WORD document
    Parameter display three-phase voltage, three- phase current, apparent power, active power, reactive power, power factor, frequency, etc.;
    Load protection Overvoltage, overcurrent, high temperature, air flow and fan failure protection;
    Fault alarm Fan failure, load high temperature alarm
    Dimension 3000*2000*2000
    Weight 2000kg
    Applicable Scope For marine diesel generator sets, land diesel generators, power inverters, UPS systems

     